دانلود رایگان مقاله انگلیسی تعیین ۴-متیل‌ایمیدازول در کم خونی کاراملی با استفاده از گاز کروماتوگرافی - هینداوی 2018

عنوان فارسی
تعیین ۴-متیل‌ایمیدازول در کم خونی کاراملی با استفاده از گاز کروماتوگرافی - طیف سنجی توده جفت
عنوان انگلیسی
Determination of 4-Methylimidazole in Ammonia Caramel Using Gas Chromatography–Tandem Mass Spectrometry (GC-MS/MS)
صفحات مقاله فارسی
0
صفحات مقاله انگلیسی
6
سال انتشار
2018
نشریه
هینداوی - Hindawi
فرمت مقاله انگلیسی
PDF
کد محصول
E8063
رشته های مرتبط با این مقاله
پزشکی
گرایش های مرتبط با این مقاله
خون شناسی
مجله
مجله کیفیت غذا - Journal of Food Quality
دانشگاه
Faculty of Food Science and Nutrition - Poznan University of Life Sciences - Wojska Polskiego - Poland
۰.۰ (بدون امتیاز)
امتیاز دهید
چکیده

One of Maillard reaction products formed in the production of ammonia caramel is 4(5)-methylimidazole (4-MeI) classifed as carcinogen. A method of 4-MeI determination based on ion-pair extraction and derivatisation with isobutyl chloroformate with subsequent gas chromatography-tandem mass spectrometry analysis was proposed. Tandem mass spectrometry was applied to reduce the infuence of matrix and increase the selectivity and sensitivity of the method. Triple quadrupole GC-MS system was used for this study. Te collision energies were optimized for MRM mode. Te detection (LOD) and quantifcation limits (LOQ) of the elaborated method were 17 and 37.8 �g kg−1, respectively, repeatability was <15% RSD for analyzed caramel samples, and the recovery for 4-MeI was 101%. Comparison of MS/MS with SIM detection on the same instrument proved almost 30 times lower LODs achieved by tandem mass spectrometry compared to SIM. Described method can be routinely used for monitoring 4-MeI as a quality and safety marker in the production of ammonia caramel.

نتیجه گیری

4. Conclusion


Described method, based on ion pairing and derivatization in sample preparation steps, followed by gas chromatography with tandem mass spectrometry was useful for determination of 4-MeI in highly complex matrix, which is ammonia caramel. As the matrix contains numerous compounds that may interfere with 4-MeI, selective extraction, derivatization, and detection were required. Te novelty of this study was the use of MS/MS for quantitation of 4-MeI. As tandem mass spectrometry virtually eliminates the infuence of matrix, especially coelution of ions of the same �/�, (as may happen in SIM), by their subsequent fragmentation, it allows more reliable quantitation and improved s/n ratio. Te method proved to be more sensitive than SIM (determined on the same instrument, approximately 30 times) and was successfully applied to control levels of 4-MeI in ammonia caramel.


بدون دیدگاه