ترجمه مقاله نقش ضروری ارتباطات 6G با چشم انداز صنعت 4.0
- مبلغ: ۸۶,۰۰۰ تومان
ترجمه مقاله پایداری توسعه شهری، تعدیل ساختار صنعتی و کارایی کاربری زمین
- مبلغ: ۹۱,۰۰۰ تومان
Observations during many earthquakes have shown that building structures are able to sustain without damage earthquake forces considerably larger than those they were designed for. This is explained by the presence in such structures of significant reserve strength not accounted for in design. Seismic codes now implicitly rely on such reserve strength. The possible sources of such strength are outlined and it is reasoned that a more rational basis for design would be to account for such sources in assessing the capacity rather than in reducing the design loads. As an exception, one possible source of reserve strength, the redistribution of internal forces, may be used in scaling down the design forces. This is because such scaling allows the determination of design forces through an elastic analysis rather than a limit analysis. In order to assess the extent of reserve strength attributable to redistribution, a series of moment-resisting steel building frames from 2 to 30 storeys is analyzed. A static nonlinear push-over analysis is used in which the gravity loads are held constant while the earthquake forces are gradually increased until a mechanism forms or the specified limit on inter-storey drift is exceeded.