Flow-accelerated corrosion (FAC) wear is the complex mechanism of damage of elements of NPP equipment and pipelines. FAC rate is determined by such factors as corrosion of metal, flow hydrodynamics, geometry of equipment elements and pipelines, applied water chemistry regimes (WCR), duration of operation, chemical composition of the metal, thickness of deposited corrosion product film and others. Approaches to the assessment of FAC rate according to the control data are addressed in the present study. Implemented investigation was aimed at the substantiation of the methodology of calculation of FAC rate. Absence of the methodology for calculation of FAC rate does not allow verification of calculation programs, as well as the use of data of regulatory documents on the minimum permissible thicknesses [1] for evaluating the residual lifetime.
Processing of measured data allowed determining the main indexes of FAC process such as the values of wall thinning and thickening, rates of wall thinning and thickening, residual operation time to the moment of reaching the minimum permissible thickness. Reduction of thickness is determined by corrosion of metal and its increase is determined by the formation of deposited film of corrosion products.